gear pumps of design version «G»
Products / GEAR PUMPS / gear pumps of design version «G»
Series 'G' ('Г') gear pumps are safe and dependable units. They are used as component of hydraulic systems of tractors, agricultural and other machines. Series 'G' ('Г') gear pumps are intended for use in hydraulic systems with pressure 160 bar and 200 bar.
| Group by displacement / Gruppe nach Foerdervolumen | 2 (4...20 ccm) | ||||||||||
| Displacement Code / Kode vomFoerdervolumen | 4 | 6 | 8 | 10 | 11 | 12 | 14 | 15 | 16 | 20 | |
|
Displacement, q Foerdervolumen, q |
cm3 ccm |
4 | 6 | 8 | 10 | 11 | 12 | 14 | 15 | 16 | 20 |
|
Maximum Continuous Pressure, P1 Dauerdruck , P1 |
MPa (bar) MPa (bar) |
16 (160) | |||||||||
|
Maximum Intermittent Pressure, P2 Kurzzeitiger Druck, P2 |
MPa (bar) MPa (bar) |
21 (210) | |||||||||
|
Maximum Peak Pressure, P3 Spitzendruck, P3 |
MPa (bar) MPa (bar) |
25 (250) | |||||||||
|
Maximum Speed, nmax Drehzahl, nmax |
min-1 min-1 |
3600 | |||||||||
|
Minimum Speed, nmin Drehzahl, nmin |
min-1 min-1 |
500 | |||||||||
| Group by displacement / Gruppe nach Foerdervolumen | 3 (20...90 ccm) | ||||||||||||||
| Displacement Code / Kode vomFoerdervolumen | 20 | 23 | 25 | 28 | 32 | 36 | 40 | 45 | 50 | 56 | 63 | 71 | 80 | 90 | |
|
Displacement, q Foerdervolumen, q |
cm3 ccm |
20 | 23 | 25 | 28 | 32 | 36 | 40 | 45 | 50 | 56 | 63 | 71 | 80 | 90 |
|
Maximum Continuous Pressure, P1 Dauerdruck , P1 |
MPa (bar) MPa (bar) |
20 (200) | 16 (160) | 14 (140) | |||||||||||
|
Maximum Intermittent Pressure, P2 Kurzzeitiger Druck, P2 |
MPa (bar) MPa (bar) |
25 (250) | 21 (210) | 17.5 (175) | |||||||||||
|
Maximum Peak Pressure, P3 Spitzendruck, P3 |
MPa (bar) MPa (bar) |
28 (280) | 23 (230) | 21 (210) | |||||||||||
|
Maximum Speed, nmax Drehzahl, nmax |
min-1 min-1 |
3600 | 3000 | 2400 | |||||||||||
|
Minimum Speed, nmin Drehzahl, nmin |
min-1 min-1 |
500 | |||||||||||||
| Group by displacement/Gruppe nach Foerdervolumen | 4 (63...200 ccm) | ||||||||||||||
| Displacement Code / Kode vomFoerdervolumen | 63 | 71 | 80 | 90 | 100 | 112 | 125 | 140 | 150 | 160 | 170 | 180 | 190 | 200 | |
|
Displacement, q Foerdervolumen, q |
cm3 ccm |
63 | 71 | 80 | 90 | 100 | 112 | 125 | 140 | 150 | 160 | 170 | 180 | 190 | 200 |
|
Maximum Continuous Pressure, P1 Dauerdruck , P1 |
MPa (bar) MPa (bar) |
20 (200) | 16 (160) | ||||||||||||
|
Maximum Intermittent Pressure, P2 Kurzzeitiger Druck, P2 |
MPa (bar) MPa (bar) |
25 (250) | 21 (210) | ||||||||||||
|
Maximum Peak Pressure, P3 Spitzendruck, P3 |
MPa (bar) MPa (bar) |
28 (280) | 23 (230) | ||||||||||||
|
Maximum Speed, nmax Drehzahl, nmax |
min-1 min-1 |
2400 | 1920 | ||||||||||||
|
Minimum Speed, nmin Drehzahl, nmin |
min-1 min-1 |
500 | |||||||||||||
|
HIII4...20G-3 |
|
HIII16...90G-3 |
|
HIII63...200G-4 |